Precision Medical PM3300 Continuous/Intermittent, (1/8 Nptf)

Details

The Three Mode Continuous & Intermittent model series provides reliable and accurate cycling of the regulator On and Off during the intermittent suctioning. The Three Mode Continuous & Intermittent series has a peak vacuum limit feature to prevent adjusting the vacuum too high. This series is ideal for sensitive applications where limiting Max vacuum is critically important. The intermittent timing cycle is factory set at 16 seconds on and 8 seconds off.

The unique modular design makes repair a breeze for any biomed or central supply department. The unit is made up of eight (8) easy-to-replace modular components.

Unlike the normal plastic inlet and outlet connections on most units, the cast metal backplate connections are extremely durable, thereby saving unnecessary repair costs.

As a result of its modular design, the unit is 25-50% smaller than other suction regulators making it the product of choice for crowded wall and rail areas.

The case is made of strong plastic. It features a smooth surface with rounded corners making cleaning easy. The case also houses the gauge for extra protection.

The large control knob with its three (3) easy-to-read settings make vacuum adjustments simple, even in emergency situations.

The Pediatric vacuum regulator is restricted to 170 mmHg (±10 mmHg) to prevent high vacuum situations and the gauge face is imprinted with the Precision Medical’s “Stork Symbol” to identify the unit for pediatric applications.

In stock
SKU
CESS-764693-00001
MPN
PM3300
Features include: Recommended Environmental Operating Limits: 55°F to 85°F (13°C to 29°C), Storage Environmental Limits: Temperature Range: -4°F to 140°F (-20°C to 60°C), Humidity: Max 95% Non-condensing
$664.05
Specifications
DiscontinuedNo
Additional Specifications:
  • Product Type: Vacuum Regulator
  • Dimensions: 3.7" (L) x 2.8" (W) x 5.2" (H)
  • Gauge Type: Anolog
  • Regulator Mode: Continuous-Intermittent 3 Mode (0-200 mmHg)
  • Vacuum Source Connection: 1/8" NPT Female
  • Patient Connection: 1/8" NPT Female
  • Vac Trap: No
  • Modes: REG. (Regulated): provides an adjustable, continuous vacuum leve, OFF: No Vacuum, INT. (Intermittent): provides an adjustable vacuum level that cycles between ON and OFF
  • Gauge Range: PM3300: 0 - 200 mmHg - Full Vacuum
  • Flow Rates: REG: 50 l/min, INT: 10 l/min
  • Gauge Accuracy: Analog: ± 5% of MAX, Digital Gauge: ± 1% of Full Scale, Analog Gauge: ± 5% of MAX within ref. Indicator
  • Maximum Vacuum: REG. Mode @ Full Vac – 396 mmHg (53 kPa)
  • Intermittent Cycle Time: Factory set at sixteen (16) seconds ON and eight (8) seconds OFF (Reference only)
  • Operating Environmental Limits: 0°F to 122°F (-18°C to 50°C)
  • Recommended Environmental Operating Limits: 55°F to 85°F (13°C to 29°C)
  • Storage Environmental Limits: Temperature Range: -4°F to 140°F (-20°C to 60°C), Humidity: Max 95% Non-condensing
  • Battery: Digital Vacuum Gauge Models only 3 Volt Lithium, ½ AA