Welch Allyn 44WT-B 4400 Series Spot Vital Signs Monitor with NIBP, Suretemp, Nonin Plug B

Details

Spot 4400 with NIBP, SureTemp Thermometer, Nonin SpO2.

In stock
SKU
CESS-774382-00001
MPN
44WT-B
Features include: Easy to navigate, easy-to-use, bp averaging with one tap, all-in-one vitals capture
$4,041.92
Specifications
DiscontinuedNo
Additional Specifications:
  • Product Type: Vital Signs Monitor
  • Dimensions: 9.3" (L) x 4.9" (W) x 10.1" (H)
  • Display Size: 7" Screen
  • Display Type: LCD Touchscreen
  • Power Source: AC Power
  • Electrical Rating: 100 – 240 V AC, 50 – 60 Hz, 0.8A – 0.5 A
  • 2 Cell Battery Usage: Up to 8 hours of Operation
  • Test Type: NIBP, Thermometer, SPO2
  • Type: Spot Check and Vital Signs Monitoring
  • Weight (Including Battery): 3.8 lbs

Graphical Display

  • Active Area: 6.1" (L) x 3.4" (H)
  • Resolution: 800 x 480 Pixels

Environmental

  • Operating Temperature: 50°F – 104°F (10°C – 40°C)
  • Storage/Transport Temperature: -4°F – 122°F (-20°C – 50°C)
  • Operating Altitude: -1250 ft – 10,000 ft (-381 m – 3,048 m)
  • Operating Humidity: 15% – 90% Noncondensing
  • Storage/Transport Humidity: 15% – 95% Noncondensing

Non-Invasive Blood Pressure (NIBP):

  • Cuff Pressure Range: Meets or Exceeds IEC/ISO 80601-2-30 Standard for Cuff Pressure Range
  • Systolic Range: Adult: 30 – 260 mmHg (StepBP, SureBP), Pediatric: 30 – 260 mmHg (StepBP, SureBP)
  • Diastolic Range: Adult: 20 – 220 mmHg (StepBP, SureBP), Pediatric: 20 – 220 mmHg (StepBP, SureBP)
  • Cuff Inflation Target: Adult: 160 mmHg (StepBP), Pediatric: 140 mmHg (StepBP)
  • Maximum Target Pressure: Adult: 280 mmHg (StepBP, SureBP), Pediatric: 280 mmHg (StepBP, SureBP)
  • Blood Pressure Determination Time: Typical: 15 seconds, Maximum: 150 seconds
  • Blood Pressure Accuracy: Meets or Exceeds ISO 81060-2:2013 Standards for NIBP (± 5 mmHg mean error, 8 mmHg standard deviation)
  • Mean Arterial Pressure (MAP) Range: Adult: 23 – 230 mmHg (StepBP, SureBP), Pediatric: 23 – 230 mmHg (StepBP, SureBP)
  • Pulse Rate Range (Using Blood Pressure Determination): Adult: 30 – 200 bpm (StepBP, SureBP), Pediatric: 30 – 200 bpm (StepBP, SureBP)
  • Pulse Rate Accuracy (Using Blood Pressure Determination): ± 5.0% (± 3 bpm)
  • Overpressure Cutoff: Adult: 300 mmHg ± 15 mmHg, Pediatric: 300 mmHg ± 15 mmHg

SureTemp Plus Temperature Module

  • Temperature Range (All Measurement Sites): 80°F – 110°F (26.7°C – 43.3°C)

SpO2

  • SpO2 Performance Measurement Range: 1% - 100%
  • Pulse Rate: 18 – 300 Bpm: ± 3 Digits; Low Perfusion (40 – 240 Bpm): ± 3 Digits
  • Saturation: 70 - 100%

Saturation Variance

  • Adult/Pediatrics, No Motion: Finger Clip: ± 2 Digits, Flex: ± 3 Digits
  • Adult/Pediatrics, Motion: Finger Clip: ± 2 Digits, Flex: ± 3 Digits
  • Adult/Pediatrics, Low Perfusion: All Sensors: ± 2 Digits
Unit of Measure (UOM)Each
© 2025 CME Corp — Delivering a Better Experience