GX solutions and the i.C3 information center set i.Series models apart by providing a professional medical-grade refrigerator with advanced monitoring control. The iPR458-GX is a four-door pass-thru pharmacy refrigerator (two doors on each side) designed for use between two spaces, such as a clean room and an ante room. This purpose-built refrigerator boasts superior stability, uniformity, and recovery alongside the added benefits of quiet operation, low heat output, and energy savings all thanks to the OptiCool advanced refrigeration technology. GX solutions pass-thru refrigerators have also undergone extensive use case testing to ensure they meet the rigorous performance requirements of a busy clinical clean room environment. This includes multiple and extended door openings. GX Solutions Pass-Thru Pharmacy refrigerators enhance pharmacy workflows and meet the requirements of pass-thru refrigerators used in USP <797> clean room applications.
Features:
OptiCool technology pairs a variable capacity compressor (VCC) and natural hydrocarbon refrigerants to ensure optimal temperature uniformity, recovery and stability, efficiently manage energy consumption and meet evolving environmental regulations
Optimized temperature uniformity, recovery and stability create the best environment for sample storage
U.S. environmental protection agency SNAP (Significant new alternatives policy) compliant refrigerants
Optional i.Lock interlocking door technology to support USP <797> compliance
Quiet operation creates fewer distractions and better working environment
i.C3 touchscreen user interface is password protected and provides advanced monitoring and information to ensure protection of stored product
Audible and visual alarms include power failure, high and low temperature alarms, door ajar, condenser temperature, and low battery
Cabinet built with high-quality construction meets or exceeds performance standards required by the medical and scientific industries
Includes certificate of calibration generated with an ISO 17025 reference thermometer
Energy-efficient LED lighting spotlights storage providing maximum illumination
Application, Rating, & Electrical Data
Facility supply rating - Branch circuit with earth ground, meeting plug/cord ratings as well as local electrical safety codes and requirements - 110-120V AC: 15 A (minimum), 220-240V AC: 10 A (minimum)
Power plug/Power cord length - NEMA 5-15 hospital-grade | 115V 60Hz, 8 to 10 ft (2.4-3.0m) Inquire about additional plug/cord options
Certification/Agency listing - QPS (Certified to UL and CSA Standards) IEC/UL61010-2-01: 2016 | IEC 61010-1:2010, AMD1:2016
Indoor/Outdoor use - Indoor use only, non-residential
Condenser temperature alarm - Yes, fully adjustable
Min/Max temperature - Yes, display and reset
Download - Yes, via USB. CSV and PDF
Event log - Yes, all alarms, door openings, download via USB
Temperature log - Yes, download via USB
Interactive temperature graph - Yes
Temperature monitoring ballast - Yes, two 4 oz bottles with screw caps, solid ballasts optional
Battery back-up - Yes, 20 hr display & alarm, 2.5 hrs with optional interlock system back up for i.C3 touchscreen | Rechargeable 12V, lead acid
Construction
Insulation - Sustainable, US EPA, and SNAP approved foam
Trim/Skirt Kit Details (sold separately )- Trim kit - side rails 3 x 81.8"; top rail 3 x 65"; Bacteria-resistant powder-coating; 1 kit per side needed, Skirt kit - 2.7 x 58.9"; Clean room side only; Bacteria-resistant powder-coating
Door - 4, dual-pane glass
Access Port - Top access port- for external monitoring probes (0.75" diameter) Left sidewall port - with interior and exterior plugs (1.75" diameter)
Interior Storage - 6 ventilated, powder coated shelves, adjustable 22.4 x 27.5", 6 liquid-tight, stainless steel, 2-way drawers, adjustable 21.5 x 4.1 x 26.9"er
Casters - Yes, swivel-locking
Interlock door optional - electronically-controlled with key switch override (prohibits doors on both sides from being opened simultaneously)
Clearance requirements - Minimum of 8" above the control side of the refrigerator. Clearance above the solid cover on the clean room side may be 0"
Pass-Thru Placement for Building-in
When placing a pass-thru refrigerator between two rooms, size the opening to fit the width of the cabinet. From front to back, the flange between the top covers indicates the separation between the clean room and ante-room (control) sides. The refrigerator should be positioned so that the wall header is over the solid cover, but not over the flange or the blue bezel. A minimum overhead clearance of 8" is required on the ante-room side of the cabinet. Zero clearance is required above the clean room side, as well as on the left and right sides of the cabinet.
Pharmacy Pass-Thru Refrigerators for Medication and Vaccine Storage
GX professional medical-grade pharmacy pass-thru refrigerators enhance pharmacy workflows when positioned between two spaces such as a clean room and an ante room. They are designed for secure storage of vaccines, pharmaceuticals, chemotherapy and other products requiring safe cold storage in a clean room environment.
For busy cleanroom compounding pharmacies with heavy ambient product loads, Helmer GX pass-thru refrigerators provide optimal refrigeration performance for safe dependable storage without nuisance alarms, even with frequent and extended door openings.
Factory pre-set to 5?C for pharmacy applications
Helps meet USP <797> clean room requirements
Supports CDC guidelines for vaccine storage
Interlock i.Lock technology electronically locks the doors when the opposite
side is opened (option on i.Series pharmacy models only)
Featured Options & Accessories
Interlocking Doors
The interlock pass-thru refrigerator is designed for use in the central pharmacy including areas built for USP compliance. The i.Lock technology allows doors on one side of the pass-thru cabinet to electronically lock when doors on the opposite side are opened
Solid Ballast Simulator Kit for GX Model Refrigerators
Solid ballast simulator is a maintenance-free thermal buffering solution designed to replace glycerin bottles. Uses existing wall or ceiling-mounted bracket
Ventilated Shelf
Full shelf, ventilated, white (with hardware). For field installation (for 26 and 58 cu ft pass-thru refrigerators)
Drawer - i.Series w/Hardware, Pass-Thru
Drawer, 2-way, liquid-tight, stainless steel (with slides), for Field Installation (for i.Series 26 and 58 cu ft pass-thru refrigerators)
Quote Information
Commercial Procurement Made Easier
New healthcare facility construction, expansion or remodel - we’ve created a
streamlined approach to healthcare supply chain for our following customers:
Medical facilities (Hospitals, Physician Offices, Long Term Care facilities,
etc.)
GPO members (Vizient, Premier, Intalere, Healthrust, ROi)
Simply search for your desired product(s), and click ‘Chat with Us for GPO Pricing!’
to connect with one of our product specialists. They will note your contact
information and any comments/questions about the item or an overall quote,
and submit it to an account manager. One of our dedicated account managers
will reach out to you with your pricing and to discuss your logistics needs
within 12 hours.
CME Makes It Easy
2 million+ products, from over 2000 manufacturers.
Contract pricing with all the major GPOs, and volume discounts for bulk orders.
We save you time and money by being your most competitive source for all items
in your PO/quote, and we’ll even locate those products we don’t carry
at the best price.
Streamlined, on-time delivery with turn-key white glove service, scheduled for
when its best for you.
Quote to Delivery. One Team. One Partner. CME Makes It Easy.